Skip to content

Zig Inline Assembly

Inline assembly lets you write CPU instructions by hand, right inside a Zig function. Let’s be honest up front: most Zig programmers never need it. The compiler writes better machine code than most of us for normal work, and Zig already has builtins for many special instructions. But when you’re writing an operating system kernel, a bootloader, or code that talks straight to the hardware, there are a few things only assembly can do. This page shows what it looks like, so you can read it when you meet it and write a little when you have to.

Reach for inline assembly only when there’s no other way:

  • Special instructions the language has no word for: reading a CPU’s tick counter, cpuid, enabling or disabling interrupts, switching page tables.
  • System calls without a C library, in a tiny static program or your own runtime.
  • Kernels, bootloaders and embedded startup code, where you set up the stack or jump to an address yourself.

And here’s what you don’t need it for, because Zig has builtins that compile to the right instruction on every CPU:

You want Use this instead
Count set bits, leading/trailing zeros @popCount, @clz, @ctz
Byte swapping @byteSwap
Fused multiply-add, square root @mulAdd, @sqrt
SIMD (several numbers per instruction) @Vector, see Zig Vectors
Atomic operations between threads @atomicLoad, @atomicRmw, std.atomic
const std = @import("std");
pub fn main() void {
const x: u32 = 0b1011_0110;
std.debug.print("{d} bits set\n", .{@popCount(x)});
std.debug.print("{d} trailing zeros\n", .{@ctz(x)});
}

Output:

5 bits set
1 trailing zeros

On an x86-64 CPU with the right features, @popCount becomes the popcnt instruction. On a CPU without it, Zig writes a fallback for you. With assembly, that fallback would be your job. Zig Builtins lists more of these.

Here’s a function that adds two numbers with the x86-64 addq instruction. It’s pointless in real code (a + b does the same), but it’s small enough to see every part:

const std = @import("std");
fn add(a: u64, b: u64) u64 {
return asm ("addq %[b], %[result]"
: [result] "=r" (-> u64),
: [a] "0" (a),
[b] "r" (b),
);
}
pub fn main() void {
std.debug.print("2 + 3 = {d}\n", .{add(2, 3)});
std.debug.print("40 + 2 = {d}\n", .{add(40, 2)});
}

Output:

2 + 3 = 5
40 + 2 = 42

An asm expression has up to four parts, separated by colons:

  1. The template, a string with the instructions: "addq %[b], %[result]". %[name] is replaced with whatever register Zig picked for that name. On x86, Zig uses AT&T syntax, where the destination comes last: addq src, dst means dst = dst + src. If you learned Intel syntax (add dst, src), this is backwards from what you’re used to.
  2. The output: [result] "=r" (-> u64). "=r" means “the result ends up in some general register”, and -> u64 makes that the value of the whole asm expression.
  3. The inputs: [a] "0" (a) and [b] "r" (b). "r" means “put b in any register”. "0" means “put a in the same register as output number 0”, so addq adds b straight into it.
  4. Clobbers (optional, not used here): registers or memory the code changes without saying so in the outputs.

The letters inside the quotes are constraints, and they come from LLVM and GCC. The language reference on assembly says this part is still considered unstable, and points you to the LLVM and GCC docs for what each letter means.

On Linux, a program asks the kernel to do things (write to a file, exit) with the syscall instruction. Normally std.Io does this for you, but here’s the raw version, writing to stdout with no library in between:

const std = @import("std");
fn write(fd: usize, bytes: []const u8) usize {
return asm volatile ("syscall"
: [ret] "={rax}" (-> usize),
: [number] "{rax}" (@as(usize, 1)), // 1 is `write` on x86-64 Linux
[fd] "{rdi}" (fd),
[ptr] "{rsi}" (@intFromPtr(bytes.ptr)),
[len] "{rdx}" (bytes.len),
: .{ .rcx = true, .r11 = true, .memory = true });
}
pub fn main() void {
const n = write(1, "Hello from a raw syscall!\n");
std.debug.print("the kernel says it wrote {d} bytes\n", .{n});
}

Output:

Hello from a raw syscall!
the kernel says it wrote 26 bytes

Three new things:

  • "{rax}" with curly braces asks for one exact register. The Linux kernel expects the system call number in rax, the arguments in rdi, rsi and rdx, and puts the result back in rax.
  • volatile tells Zig “this has side effects, keep it even if nobody uses the result”. Without it, the optimizer is allowed to delete an asm whose output is unused, and a syscall that prints something must never be deleted.
  • The clobber list .{ .rcx = true, .r11 = true, .memory = true } is a struct literal of what the code destroys. The syscall instruction overwrites rcx and r11, so Zig must not keep anything there. .memory = true says the code may read or write memory Zig doesn’t know about (here, the kernel reads our string).

A more realistic use: x86 CPUs have a time-stamp counter that ticks very fast, and the rdtsc instruction reads it. No builtin does this, so assembly it is. rdtsc puts the low 32 bits in eax and the high 32 bits in edx:

const std = @import("std");
fn rdtsc() u64 {
var low: u32 = undefined;
var high: u32 = undefined;
asm volatile ("rdtsc"
: [low] "={eax}" (low),
[high] "={edx}" (high),
);
return (@as(u64, high) << 32) | low;
}
pub fn main() void {
const before = rdtsc();
var sum: u64 = 0;
for (0..1000) |i| sum += i;
const after = rdtsc();
std.debug.print("sum = {d}, took about {d} CPU ticks\n", .{ sum, after - before });
}

You’ll see something like:

sum = 499500, took about 2908 CPU ticks

The tick count changes every run. Here the outputs are bound to variables ((low), (high)) instead of using -> type, which is how you get more than one value out. For timing real code, prefer the portable clocks from Zig Performance; rdtsc is for when you need the raw counter.

Assembly is written for one CPU family. Everything on this page is x86-64. Try to build the add example for a 64-bit ARM Linux machine:

Terminal window
zig build-exe add.zig -target aarch64-linux
error: <inline asm>:1:2: unrecognized instruction mnemonic, did you mean: add, addp, adds, addv, fadd, madd?
addq x2, x0
^

ARM has no addq. The syscall example fails even earlier, because the clobber struct for ARM has no rcx field: error: no field named 'rcx' in struct 'lang.assembly.Clobbers__struct_32'. Even on the same CPU, system call numbers differ between operating systems, so write above is x86-64 Linux only.

The usual fix is to check the target at compile time and keep a plain Zig version for everything else:

const std = @import("std");
const builtin = @import("builtin");
fn add(a: u64, b: u64) u64 {
if (builtin.target.cpu.arch == .x86_64) {
return asm ("addq %[b], %[result]"
: [result] "=r" (-> u64),
: [a] "0" (a),
[b] "r" (b),
);
} else {
return a + b; // plain Zig everywhere else
}
}
pub fn main() void {
std.debug.print("2 + 3 = {d}\n", .{add(2, 3)});
}

Output:

2 + 3 = 5

builtin.target.cpu.arch is known at compile time, so only one branch is compiled. This version builds for aarch64-linux and riscv64-linux too (we checked). That’s exactly how the standard library handles it: per-CPU assembly where it must, with a separate file or branch for each architecture. Zig Cross-Compilation shows how to build for other targets.

Write sub(a, b) that returns a - b using the x86-64 subq instruction, and print sub(10, 3).

Hint: copy add and change only the instruction. In AT&T order, subq %[b], %[result] means result = result - b.

Show solution
const std = @import("std");
fn sub(a: u64, b: u64) u64 {
return asm ("subq %[b], %[result]"
: [result] "=r" (-> u64),
: [a] "0" (a),
[b] "r" (b),
);
}
pub fn main() void {
std.debug.print("10 - 3 = {d}\n", .{sub(10, 3)});
}

Output:

10 - 3 = 7

The "0" constraint puts a in the result register first, and subq takes b away from it. Swap the operands in the template and you’d get b - a, a typical AT&T mix-up.

Write exit(code) that calls the Linux exit system call (number 60 on x86-64) with the code in rdi. Call exit(0) at the end of main, after printing a line.

Hint: it never returns, so make the function return noreturn, use asm volatile with no outputs, and put unreachable; after it. The output section is then empty, so the line starts with : straight away.

Show solution
const std = @import("std");
fn exit(code: usize) noreturn {
asm volatile ("syscall"
:
: [number] "{rax}" (@as(usize, 60)), // 60 is `exit` on x86-64 Linux
[code] "{rdi}" (code),
: .{ .rcx = true, .r11 = true });
unreachable;
}
pub fn main() void {
std.debug.print("about to exit\n", .{});
exit(0);
}

Output:

about to exit

The empty output section is the lone : line. In real programs use std.process.exit, which does this for every operating system Zig supports.

  • You rarely need inline assembly. Builtins like @popCount, @byteSwap, @Vector and atomics cover most special instructions portably.
  • An asm expression has a template, outputs, inputs and clobbers, separated by colons. %[name] refers to an operand.
  • On x86, Zig uses AT&T syntax: the destination comes last.
  • volatile keeps assembly with side effects from being optimized away. Clobbers list what the code destroys.
  • Constraint mistakes don’t cause compile errors, they cause silent bugs. Keep asm blocks tiny.
  • Assembly is not portable: check builtin.target.cpu.arch at compile time and keep a plain Zig fallback.

Next up: Zig & WebAssembly, building Zig code that runs in a browser or in Node.js.

Quick check

1. You need to count the set bits in a u64. What should you use?
2. In Zig's x86 assembly, what does addq %[b], %[result] do?
3. Why does the syscall example use asm volatile?
4. You build code with x86-64 assembly for aarch64-linux. What happens?